2 resultados para patient outcomes

em Repositório do Centro Hospitalar de Lisboa Central, EPE - Centro Hospitalar de Lisboa Central, EPE, Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Patient-controlled epidural analgesia with low concentrations of anesthetics is effective in reducing labor pain. The aim of this study was to assess and compare two ultra-low dose regimens of ropivacaine and sufentanil (0.1% ropivacaine plus 0.5 μg.ml-1 sufentanil vs. 0.06% ropivacaine plus 0.5 μg.ml-1 sufentanil) on the intervals between boluses and the duration of labor. MATERIAL AND METHODS: In this non-randomized prospective study, conducted between January and July 2010, two groups of parturients received patient-controlled epidural analgesia: Group I (n = 58; 1 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil) and Group II (n = 57; 0.6 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil). Rescue doses of ropivacaine at the concentration of the assigned group without sufentanil were administered as necessary. Pain, local anesthetic requirements, neuraxial blockade characteristics, labor and neonatal outcomes, and maternal satisfaction were recorded. RESULTS: The ropivacaine dose was greater in Group I (9.5 [7.7-12.7] mg.h-1 vs. 6.1 [5.1-9.8 mg.h-1], p < 0.001). A time increase between each bolus was observed in Group I (beta = 32.61 min, 95% CI [25.39; 39.82], p < 0.001), whereas a time decrease was observed in Group II (beta = -1.40 min, 95% CI [-2.44; -0.36], p = 0.009). The duration of the second stage of labor in Group I was significantly longer than that in Group II (78 min vs. 65 min, p < 0.001). CONCLUSIONS: Parturients receiving 0.06% ropivacaine exhibited less evidence of cumulative effects and exhibited faster second stage progression than those who received 0.1% ropivacaine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). RESULTS: 312 patients were included with a median follow-up of 37.7months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27-0.93, p=0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27-0.82, p=0.008). After multivariate survival analysis, overall survival was independently associated with younger age, higher LVEF, NYHA class lower than 3 and RM. CONCLUSION: RM was independently associated with increased long-term survival and a lower incidence of a composite endpoint of hospitalization for HF or cardiovascular mortality.